Welcome to Guangdong Sino Union International Testing!

Chinese

Test service Authentication service Consult service Solution
  • 2G/3G/4G RF test system

    • describe

      The Agilent 8960 comprehensive test instrument and the German R&S CMW500 broadband wireless communication test equipment and signal analyzer, high performance vector signal generator instrument, composed of a complete set of 2G/3G/4G RF test Solution. A system that supports a wide range of different communication systems, can be customized according to different needs of customers different testing capabilities。
    • testing capability

      Can be used for RF test of GSM / GPRS / EDGE / CDMA2000 / EVDO / TD-SCDMA / WCDMA / HSDPA / HSUPA / HSPA+ / LTE FDD / LTE TDD and other standard products, the RF index covering all upstream and downstream, including frequency difference, phase difference, modulation, power, power control, channel leakage, envelope, spectrum, spurious, sensitivity, co channel interference, adjacent channel interference, intermodulation, blocking and so on. Fully meet the RF testing requirements of CE / FCC / IC / TELEC and other mainstream authentication.
    • Standard support

      EN 301 511
      EN 301 526
      EN 301 908-1v
      EN 301 908-2
      EN 301 908-4
      EN 301 908-6
      EN 301 908-13
      FCC Part 22H
      FCC Part 24E
      FCC Part 27
      IC RSS-132
      IC RSS-133
      IC RSS-199
      MIC Notice No.88 Annex 29&30&79
  • Bluetooth radio frequency test system

    • describe

      Germany R&S CBT, Bluetooth tester and other high-performance testing instruments, to form a complete set of Bluetooth frequency test Solution. Provides full Bluetooth 1.2, 2 + EDR, 2.1 + EDR, 3 + HS (high speed) and 4 RF test capabilities. Different testing capabilities can also be customized according to different requirements of customers, which is a good choice for prediction or certification test。
    • Testing ability

      Can be used for Bluetooth 1.2, 2 + EDR, 2.1 + EDR, 3 + HS (high speed) and 4 CE / FCC / IC / TELEC and other mainstream certification test RF test, including spurious (CSE), frequency error, modulation accuracy (EVM), transmission power, power spectral density, bandwidth (OBW band edge), etc..。
    • Standard support

      EN 300 328
      FCC Part 15C
      IC RSS-210
      MIC Notice No.88 Annex 43&44
  • WIFI RF test system

    • describe

      The scheme mainly adopts the Japanese security MT8860C WLAN tester and high performance spectrum meter. Provide full WIFI 802.11 a/b/g/n RF Testing ability. Different Testing ability can also be customized according to different requirements of customers, which is a good choice for prediction or certification test.
    • Testing ability

      Can be used for the WIFI 802.11 a/b/g/n product of CE / FCC / IC / TELEC and other mainstream certification test RF test, including spurious (CSE), frequency error, modulation accuracy (EVM), transmission power, power spectral density, bandwidth (OBW), band edge, dynamic frequency selection (DFS) and so on.
    • Standard support

      EN 300 328
      EN 301 893
      FCC Part 15C
      FCC Part 15E
      IC RSS-210
      MIC Notice No.88 Annex 43&44&45&47
  • Short distance radio frequency test system (SRD)

    • describe

      The main use of the United States Agilent PSA or PXA series of high-performance spectrometer and other instruments. Provide RF Testing ability for various SRD products. Different Testing ability can also be customized according to different requirements of customers, which is a good choice for prediction or certification test。
    • Testing ability

      CE, FCC / IC and other mainstream authentication RF test for SRD products, such as remote control, remote control toy, driving recorder, RFID and so on. The test includes spurious (CSE), frequency error, modulation accuracy (EVM), transmission power, power spectral density, output spectrum, bandwidth (OBW), band edge, sensitivity, co channel interference, adjacent channel interference, intermodulation, receive receiver blocking etc.
    • Standard support

      EN 300 220-1/2
      EN 300 330-1/2
      EN 300 440-1/2
      EN 302 291-1/2
      EN 302 208-1/2
      FCC Part 15C
      IC RSS-210
  • SAR/HAC preparation of human tissue fluid

    Guangdong China International testing technology SAR/HACLaboratory can be prepared according to international standards for SARLaboratory test required tissue fluid, covering 300MHz to 3GHz frequency. All formulations and specifications are fully in line with IEEE1528 and FCC OET65 standards.

    in accordance with IEEE1528 and FCC OET65 standards, sugar, sodium chloride, hydroxyethyl cellulose and other raw materials in accordance with the proportion of mixed. The dielectric constant and conductivity and fine-tuning of tissue fluid, tissue fluid and body tissue after debugging calibrated the dielectric constant and conductivity is similar to that used in the domestic and international certification testing and enterprise production and development.

    in the actual SAR test, the tissue fluid is used in a fixed human model to absorb the electromagnetic energy released by the measured object, and the corresponding test results are obtained by data acquisition system and software calculation. For different parts of human body and different frequencies, the dielectric constant and conductivity of the tissue fluid are different.

    Solution Guangdong international testing technology can provide you with tissue fluid.